Radiography: IR Exposure (Chapter 26)

71 flashcardsby Z
Study these flashcardsFree · spaced repetition · iPhone, Android, Mac & web

All cards

1
Which two photographic properties determine visibility of detail in the radiographic image?
1. Densityrightness; 2. Contrast
2
What word describes image density when a digital radiograph is viewed on a monitor?
Brightness
3
Which digital post-processing controls change displayed brightness and grayscale?
Window and level
4
For radiographic images, what is the main controlling factor of image receptor exposure?
mAs
5
What is the approximate minimum change in mAs that produces a perceptible change in film density?
30%
6
Why is doubling or halving mAs preferred over a tiny adjustment when repeating an exposure?
To ensure a sufficiently noticeable exposure change
7
What is the step-in-time rule, and why should it be avoided?
Changing mAs by an arbitrary small time step; equipment differences make results unreliable
8
If you want to change IR exposure without changing contrast, which technical factor should you primarily alter?
  • kVp
  • SID
  • mAs
  • Grid ratio
9
What does raising kVp generally do to receptor exposure, with other factors constant?
Increases it
10
What does a 15% increase in kVp do to image receptor exposure according to the 15% rule?
Approximately doubles it
11
What does a 15% decrease in kVp do to image receptor exposure according to the 15% rule?
Approximately halves it
12
Why is adjusting kVp to change exposure different from adjusting mAs?
Changing kVp also changes radiographic contrast
13
An elbow was exposed at 60 kVp. Using the 15% rule, what whole-number kVp approximately halves IR exposure?
51 kVp
14
An abdomen was exposed at 75 kVp. Using the 15% rule, what whole-number kVp approximately doubles IR exposure?
86 kVp
15
A distal femur was exposed at 65 kVp. Using the 15% rule, what whole-number kVp approximately halves IR exposure?
55 kVp
16
Compared with a single-phase generator at the same selected factors, what happens to receptor exposure with a high-frequency generator?
It increases
17
When converting from single-phase to high-frequency generation, which mAs conversion factor maintains exposure?
0.5
18
When converting from high-frequency to single-phase generation, which mAs conversion factor maintains exposure?
2.0
19
A satisfactory single-phase exposure uses 20 mAs. What mAs maintains exposure with a high-frequency generator?
10 mAs
20
A satisfactory high-frequency exposure uses 4 mAs. What mAs maintains exposure with a single-phase generator?
8 mAs
21
What happens to film density when focal-spot size is changed on a properly calibrated radiographic unit?
Negligible change
22
High tube current causes an unwanted increase in effective focal-spot size from reduced electron focusing. What is this called?
Blooming
23
Where is beam intensity greater because of the anode heel effect?
Cathode end
24
For an object thicker at one end, where should the thicker portion be positioned to use the anode heel effect?
Toward the cathode end
25
When is the anode heel effect more pronounced: short SID or long SID?
Short SID
26
What happens to radiation intensity at the IR when distance increases with technique factors unchanged?
Decreases according to the inverse-square law
27
Which relationship calculates how exposure intensity changes with distance?
I₁/I₂ = D₂²/D₁²
28
An exposure measures 180 mR at 40 inches. What intensity is expected at 72 inches with the same technique?
55.6 mR
29
What formula adjusts mAs to maintain receptor exposure after changing SID?
New mAs = Original mAs × (new SID/old SID)²
30
A satisfactory exposure uses 20 mAs at 72 inches. What mAs maintains exposure at 40 inches?
6.17 mAs
31
A satisfactory exposure uses 10 mAs at 40 inches. What mAs maintains exposure at 52 inches?
16.9 mAs
32
What happens to receptor exposure when filtration is increased without changing other technique factors?
Decreases
33
What minimum total filtration is recommended above 70 kVp?
2.5 mm aluminum
34
When beam restriction is increased through tighter collimation, what happens to scatter and IR exposure?
Both decrease
35
As anatomical part thickness increases, what happens to IR exposure with the same technique?
Decreases
36
How should a body part inside a cast be treated when planning exposure technique?
As a thicker or denser anatomical part
37
How does adding a grid affect IR exposure at unchanged factors?
It decreases because the grid absorbs radiation
38
When using a grid with a higher conversion factor, what must happen to mAs to maintain receptor exposure?
Increase mAs
39
Which formula maintains exposure when changing grids?
New mAs = Old mAs × (new GCF/old GCF)
40
As film-screen relative speed increases, what happens to mAs needed for equal density?
Decreases
41
What is the relative-speed exposure maintenance formula?
New mAs = Old mAs × (old relative speed/new relative speed)
42
An acceptable image uses 10 mAs with a 400-speed system. What mAs is required with a 200-speed system?
20 mAs
43
Why can digital post-processing fail to rescue a severely underexposed image?
Missing image information cannot be restored by changing its appearance
44
Which pathological change generally increases IR exposure with unchanged factors?
  • Additive pathology
  • Destructive pathology
  • Increased patient thickness
  • Higher grid ratio
45
Which pathological type decreases IR exposure: additive or destructive?
Additive pathology
46
How does radiolucent contrast media affect IR exposure?
Increases it
47
How does radiopaque contrast media affect IR exposure?
Decreases it
48
What effect does increasing generator waveform pulses have on IR exposure?
Increases it
49
Which imaging modality uses the term density for the degree of image blackening?
Analog screen-film radiography
50
What distinguishes a soft-copy radiograph from a hard-copy radiograph?
Soft copy is displayed digitally, whereas hard copy is printed on film
51
Approximately how many shades of gray can a person distinguish at one time?
30
52
What is the purpose of a preset, examination-specific digital image histogram?
To guide image processing for that examination
53
Why can acceptable digital image brightness be misleading when evaluating an exposure?
Post-processing can alter brightness without restoring missing information
54
Can a radiographic image have exposure without contrast, or contrast without exposure?
Exposure without contrast is possible, but contrast requires exposure
55
What is the relationship of kVp to IR exposure: controlling or influencing factor?
Influencing factor
56
If kVp is increased by 15% but receptor exposure must remain approximately unchanged, what should happen to mAs?
Halve mAs
57
Which generator produces lower average photon energy at comparable selected kVp?
  • High frequency
  • Three-phase 12-pulse
  • Single-phase
58
What should be done if focal-spot blooming causes noticeable density differences?
Perform quality control and evaluate the x-ray tube
59
By up to what percentage can exposure be greater at the cathode end than the anode end?
45%
60
How does opening the collimator field affect the prominence of the anode heel effect?
Makes it more pronounced
61
What is the other name for the exposure maintenance formula relating mAs and SID?
Direct square law
62
An exposure measures 240 mR at 72 inches. What intensity is expected at 40 inches with unchanged technical factors?
777.6 mR
63
An exposure measures 110 mR at 52 inches. What intensity is expected at 40 inches with unchanged technical factors?
185.9 mR
64
A satisfactory image uses 40 mAs at 72 inches. What mAs maintains receptor exposure at 45 inches?
15.63 mAs
65
What minimum total filtration is recommended at 50–70 kVp?
1.5 mm aluminum
66
What minimum total filtration is recommended below 50 kVp?
0.5 mm aluminum
67
Why is filtration beyond 3 mm aluminum considered a point of diminishing returns?
Further reduction in entrance skin exposure may not justify increased tube loading
68
How does increasing tissue atomic number affect receptor exposure, assuming comparable thickness and unchanged technique?
Decreases it
69
Which factor has a negligible overall effect on IR exposure?
  • Increasing filtration
  • Increasing grid ratio
  • Anode heel effect
  • Increasing distance
70
What happens to film density when developer time, temperature, or chemical activity increases?
Increases
71
What effect does contaminated film-processing solution have on film density?
Decreases it
Study all 71 cards for free

More Medicine & health flashcards

Micosis superficiales21 cardsMedicine & health · SpanishMajoStrep Throat16 cardsMedicine & health · Englishcae4- sys. lymphatique12 cardsMedicine & health · FrenchOcéaneChapter 12: Brain Anatomy and Functions68 cards · 1 addedMedicine & health · EnglishElmindredaShoulder Anatomy and Radiography (Ch 4-5)302 cardsMedicine & health · EnglishZSports Medicine: Injury Management and Athlete Health109 cardsMedicine & health · EnglishAndySkeletal System81 cardsMedicine & health · EnglishEmelySensory Receptors and Transduction (Chapter 11)63 cardsMedicine & health · EnglishKrisMedCardsLecture 7 — Infection, Virulence, and Epidemiology51 cardsMedicine & health · Englishlavinia1- synapse + GABA41 cardsMedicine & health · FrenchOcéaneCoordination and response33 cardsMedicine & health · EnglishAli_vxxxThe respiratory system27 cardsMedicine & health · Englishizsquibb

All Medicine & health decks

Study these decks in the app

Free on iPhone, Android, Mac and the web. Add any deck to your account in one tap.

Download on the App StoreGet it on Google Play
Study all 71 cards for free