Mounting Media in Cytology

48 flashcardsby CHRISTY
Study these flashcardsFree · spaced repetition · iPhone, Android, Mac & web

All cards

1
This syrupy fluid (also called a mountant) is applied between the section and the coverslip after staining to set the section firmly, prevent coverslip movement, and protect against physical injury and stain oxidation.
Mounting medium
2
This is the Refractive Index (RI) of glass, which the best mounting medium should closely match so tissue detail is clearly visible.
1.518
3
These are the eight properties of the best mounting medium.
RI close to glass (1.518), freely miscible with xylene and toluene, does not dry quickly, does not change in pH or color, does not cause tissue shrinkage/distortion, does not dissolve or fade tissue sections, does not leech out stain, and sets hard without cracking or artifactual granularity
4
This group of water-soluble mountants is designed to mount water-miscible preparations directly from water when the stain would be removed or decolorized by alcohol or xylene.
Aqueous / Water-soluble Mountants
5
These are the five aqueous/water-soluble mountants and their key refractive indices or features.
Water, Glycerin (RI 1.47), Farrant's medium/Gum syrup (RI 1.43; gum arabic, DW, glycerol, sodium Merthiolate; does not need heating), Apathy's medium (used for Methylene Blue-stained nerve preparations and as a general aqueous mountant), and Brun's fluid (recommended for mounting frozen sections from water)
6
This group of mountants is used for preparations that have been dehydrated and cleared in xylene or toluene, and is recommended for the majority of staining methods.
Resinous Mountants
7
This natural resin extracted from the Canadian tree Abus balsamea has an RI of 1.524, is miscible with xylene, is expensive, and is recommended for whole mounts and thick sections because it does not shrink much.
Canada Balsam
8
This synthetic resinous mountant (Dibutyl phthalate polystyrene xylene) has an RI of 1.532 and is recommended for small tissue sections.
DPX
9
This synthetic resin mixture in xylene is a pale yellow or colorless solution with an RI of 1.52.
Xam
10
This synthetic resinous mountant has an RI of 1.544, is usually diluted to 60% with xylene, and is generally preferred over DPX.
Clarite
11
These are the three other recommended synthetic mounting media and their manufacturers.
Permount (Fisher Scientific), H.S.R. (Harleco Synthetic Resin), and Clearmount (Gurr)
12
These are the five permanent mounting media (resins soluble in alcohol).
Canada Balsam, D.P.X., Clarite, Eukit, and Entellan
13
These seven semi-permanent and temporary mounting media are used when permanent xylol-resin mountants would dissolve essential stains (such as fat stains like Oil Red O and Sudan IV).
Water, Glycerin (glycerol), Mineral oil (Liquid Paraffin), Glycerin Jelly (Glycerol Gelatin), Von Apathy's Gum Syrup Medium, Farrant's Medium, and Levulose (Fructose) Syrup
14
This is how excessive mounting medium that oozes out of the cover glass is removed, and how a cover glass is removed if a section needs remounting.
Excess mountant is wiped with a fine cloth moistened with xylene; the cover glass is removed by soaking in xylene
15
This is the effect of excessive blotting (too little mountant) during mounting.
It dries up the section, causing shrinkage and cracking of the specimen
16
This process seals the margins of the coverslip to prevent fluid escape or evaporation, immobilize the coverslip, and prevent slides from sticking during storage.
Ringing
17
This ringing cement is made of 2 parts paraffin mixed with 4–9 parts powdered Colophonium resin, heated and filtered.
Kronig Cement
18
This is how a broken slide is temporarily salvaged for immediate examination, or permanently saved if intact and no replacement is available.
Mount the broken slide onto another xylene-moist slide with a drop of Clarite or Permount; if intact, transfer the section to another slide
19
These are the two mounting media most commonly used today, and the hot oven temperature utilized for mounting sections that are not properly dehydrated.
Eukit and Entellan; 50°C hot oven
20
This branch of pathology involves the microscopic examination of cells from different body sites for diagnostic purposes, divided into Fine Needle Aspiration (FNA) and Exfoliative Cytology.
Diagnostic Cytology
21
This cytology technique studies cellular samples obtained from organs that do not shed cells spontaneously (breast, thyroid, lymph nodes, liver, lungs, skin, soft tissues, bones) using a 22-gauge needle and a 10-mL syringe.
Fine Needle Aspiration (FNA)
22
This is why FNA samples from mesenchymal cells (connective tissues) require a larger bore needle, increased suction, and rapid air drying.
Mesenchymal cells tightly adhere to each other and do not exfoliate easily; rapid air drying reduces the effects of shrinkage
23
This branch of cytology deals with the microscopic study of cells desquamated from epithelial surfaces (spontaneously shed or physically removed).
Exfoliative Cytology
24
These are the five main clinical indications for Exfoliative Cytology.
Detection of malignant cells in body fluids, detection of precancerous cervical lesions in women, assessment of female hormonal status in sterility/endocrine disorders, determination of genetic sex (Barr bodies / XX chromosomes), and detection of infectious agents
25
These are the eight common specimen sites for Exfoliative Cytology.
Cervicovaginal smears (Pap smear), endometrial/endocervical smears, prostaticreast secretions, gastricronchial secretions, pleural/peritoneal fluids, sputum, smears of urine sediments, and cerebrospinal fluid (CSF)
26
This staining method is the choice for exfoliative cytology, consisting of Hematoxylin (nucleus), Orange G6 in 95% alcohol (mature cells/MSC), Eosin Azure 50 (immature/intermediate/parabasal cells), and Phosphotungstic acid (main pH-controlling agent).
Papanicolaou Staining
27
This is the new system of reporting cervical and vaginal cytologic diagnoses.
The Bethesda System
28
These are the two ways body fluids are prepared for microscopic cytologic study.
Smear techniques and preparation of tissue blocks (cell block)
29
These are the recommended fixatives for cervical/vaginal smears, sputumronchopulmonary specimens, pleural/peritoneal fluids, and gastric specimens.
Cervical/vaginal: 95% ethanol and ether or 95% ethanol; Sputum: 95% ethanol (cough directly into container) or Brasil's fixative; Pleural/peritoneal: Brasil's fixative; Gastric: 95% ethanol
30
These are the alcohol concentrations and Saccomanno's fixative composition used for fixing fluid specimens.
50% alcohol for all types of effusions, 50% for peritoneal/pleural fluids, 70% for sputum, and 95% for urineastricronchial aspirates; Saccomanno's fixative (50% ethanol and 2% carbowax) is the fixative of choice for sputum
31
These are the speed and duration for centrifugation of fluid specimens, and the three methods for cell block preparation from extra sediment.
2000 rpm for 2 minutes; extra sediment is prepared via filtration, plasma thrombin, or carbowax
32
This is the best method to collect cells on body fluid, using a cytocentrifuge at 2000 rpm for 1 minute to concentrate cells onto a microscope slide.
Cytospin Preparation
33
These are the three fixatives used for cytologic smears, including the best fixative and the most commonly used fixative.
Equal parts of 95% ethanol and ether (best fixative), 95% ethanol (most commonly used), and spray fixative (held at 1 foot distance)
34
These are the five precautions to observe during smear fixation.
Proper identification before preparing smears, batch fixing to avoid sticking of slides, immediate placement into fixative container after preparation, placing each smear in a single uninterrupted motion to avoid rippling, and avoiding vibration to prevent dislodging cells
35
This technique for bronchial brushings directly smears the specimen on both slides and fixes immediately to avoid producing clotting artifacts.
Pull-apart technique
36
This non-gynecologic respiratory specimen is usually performed in patients with AIDS to rule out Pneumocystis carinii.
Bronchoalveolar Lavage (BAL)
37
These are the collection and adequacy criteria for sputum specimens in cytology.
Obtain at least 3 consecutive morning specimens (deep cough) in a wide-mouthed jar with Saccomanno's fixative (or use aerosol solution inhalation for 20 minutes); alveolar macrophages determine deep-cough adequacy (absence indicates saliva only)
38
This anticoagulant is added per 100 mL of serous effusion aspirate (peritoneal, pericardial, pleural) to prevent jelly-like clot formation.
300 units of heparin
39
This is what bloody breast secretion smears typically indicate, along with their general diagnostic utility.
Benign intraductal papilloma; used for hormonal imbalance testing, with low diagnostic yield for breast carcinoma
40
This volume of cerebrospinal fluid (CSF) is needed for cytologic examination.
1 mL
41
These are the three types of gastrointestinal smear specimens, the required fasting time, and their main purpose.
Gastric brush, gastric lavage, and submucosal lesion fine needle aspirate; patients must fast at least 8 hours (even water is prohibited); usually done to exclude malignant tumors
42
These are the specimen volume and collection requirements for urine specimens in cytology.
Mainly diagnoses urothelial malignancy (not prostatic carcinoma); 50 mL is needed, the 2nd urine is examined (1st urine is discarded), and preservatives are not recommended
43
This anatomical junction of endocervical and ectocervical mucosa is where the majority of cervical carcinomas and precancerous lesions arise.
Transformation Zone (T-Zone)
44
These three cell types must be present in an optimal gynecologic Pap smear sample.
Squamous, columnar, and metaplastic cells
45
These are the six specific collection sites and methods for gynecologic cytology.
Endocervical brush (endocervical canal), vaginal scrape (patients with hysterectomy), lateral vaginal scrape (hormonal evaluation), four-quadrant vaginal scrape (localization of vaginal adenosis), and vulvar scrape (herpetic lesions or carcinoma)
46
These are the three pieces of equipment used for vaginal, endocervical, and endometrial aspirations.
Glass pipette and rubber bulb (vaginal aspiration), Ayre's spatula (swab smear), and laryngeal cannula attached to a 10-cc syringe (endocervical/endometrial aspiration)
47
Who discovered the Pap smear and when, and what is its clinical role?
Discovered by Dr. George Papanicolaou in the 1940s; defined as a screening tool to detect precancerous conditions (not diagnostic)
48
These are the five classes of the Papanicolaou Method of Reporting and their descriptions.
Class I: Absence of atypical/abnormal cells (normal cytology); Class II: Atypical cytology, no evidence of malignancy (26–49% atypical; infection/inflammation); Class III: Cytology suggestive of, but not conclusive for malignancy (doubtful; 50% undifferentiated cells); Class IV: Cytology strongly suggestive of malignancy (fairly malignant; 51–75% undifferentiated; early cancer); Class V: Cytology conclusive for malignancy (76–100% undifferentiated; with metastasis)
Study all 48 cards for free

More Medicine & health flashcards

Joints63 cardsMedicine & health · EnglishNot3- vision51 cardsMedicine & health · FrenchOcéaneChest X rays41 cardsMedicine & health · EnglishfaithSensory Physiology33 cardsMedicine & health · EnglishKatlynKEAnisochromia27 cardsMedicine & health · EnglishCHRISTYhypertensives drugs21 cardsMedicine & health · Englishoozuvenipuncture17 cardsMedicine & health · Englishelijahmuscle fibers 12 cardsMedicine & health · EnglishnewTkanka łączna - Histologia68 cards · 1 addedMedicine & health · PolishLuvenHead & Neck Anatomy319 cardsMedicine & health · EnglishEmmaImmunology: Antibodies and Immunoglobulins108 cardsMedicine & health · EnglishJESSQTRANGABAergic Synapses and Neurotransmission80 cardsMedicine & health · EnglishMoll

All Medicine & health decks

Study these decks in the app

Free on iPhone, Android, Mac and the web. Add any deck to your account in one tap.

Download on the App StoreGet it on Google Play
Study all 48 cards for free