Additional flashcards

28 flashcardsby shelly
Study these flashcardsFree · spaced repetition · iPhone, Android, Mac & web

All cards

1
The portion of precipitation that returns to the atmosphere without hitting the ground is called __________ _______ (eg. water evapoarting off plant leaves)
interception loss
2
The upper boundary of an unconfined aquifer is the ______ ______.
water table
3
Which type of aquifer is more vulnerable to suface contamination (eg. agriculture, oil spills): confined or unconfined?
unconfined
4
Which type of aquifer has more stable water levels: confined or unconfined?
confined
5
Which type of aquifer can create artesian wells due to being under pressure: confined or unconfined?
confined
6
An aquifer that CANNOT quickly replace water that is pumped from it will have a ____ (high / low) drawdown.
high
7
Driven wells aka "sand point wells" are only allowed for which type of use: private residential or municipal?
private residential
8
A Community Water System (CWS) serves at least ___ residential service connections OR at least ____ residents year-round.
15 25
9
Other-Than-Municipal (OC) Community Water Systems are Community Water Systems that serve at least 25 year-round residents from _________ ______, eg. trailer parks, condos, long-term care facilities.
private wells
10
A well's efficiency can be measured by it's __________ __________ (gpm/ft), which is the rate of water discharge per unit drawdown.
specific capacity
11
Well operators would prefer to see a well's specific capacity ___________ (increase / decrease).
increase
12
A well that pumps little water while having a high impact on aquifer water levels (eg. high drawdown) has a ______ (high / low) specific capcity.
low
13
A ______ (rise / drop) in static and pumping water levels of a well might be attributed to drought conditions or a well in need of rehab.
drop
14
A well must be abandoned if it's contaminated with pathogens and ____ attempts to disinfect it fail.
3
15
A well must be abandoned if it's been out of service for _____ days or more.
90
16
A well must be abandoned if it's been "temporarily out of service" for ____ years or longer.
5
17
Positive displacement pumps can be rotary style or ____________ style.
reciprocating
18
Dug, bored, and driven wells are examples of ________ (private / municipal) wells.
private
19
Drilled, radial, and caisson wells are examples of __________ (private / municipal) wells.
municipal
20
Operating a pump outside of it's spec (higher or lower rate than design) can lead to well ___________, which is small bubble of water vapor in the well that makes a gravelly/clinking sound.
cavitation
21
Which type of impeller is best for pumping water with no solids present: closed, open, semi-open, or split?
closed
22
If you can't tighten the packing gland any further, you should _________ the packing.
replace
23
Polyphosphates can help solve water quality problems resulting from _______ contaminants.
inorganic
24
Water quality issues arising from iron, manganese, calcium like color, scale, corrosion, and chlorine demands can be addressed with the addition of ____________ which work by binding up metals to keep them soluble in water.
polyphosphates
25
Why add sodium hydroxide?
Increase pH to reduce corrosion
26
Inject chlorine ( before / after ) check valve.
after
27
Inject polyphosphate after check valve but before...
chlorine
28
Inject sodium hydroxide and hydrofluoric acid after the last...
gate valve
Study all 28 cards for free