Hematology Section (Hema Part 1)

146 flashcardsby MARIA
Study these flashcardsFree · spaced repetition · iPhone, Android, Mac & web

All cards

1
It is a branch of medicine concerning the study of blood, the blood-forming organs and blood diseases.
Hematology
2
In the medical field, it includes the treatment of blood disorders and malignancies including types of hemophilia, leukemia, lymphoma and sickle cell anemia
Hematology
3
EACMed Hematology Section Offers:
• Complete blood count (CBC)
• Coagulation Studies: Prothrombin time, Activated Partial Thromboplastin Time (APTT) and D-dimer
• Erythrocyte Sedimentation Rate (ESR)
• Reticulocyte Count
• Clotting Time & Bleeding Time
• Malarias Smear
• Peripheral Blood Smear (PBS)
4
What specimen is used in Complete Blood Count (CBC)?
EDTA Whole blood (Lavender Top)
5
What specimen is used in Erythrocyte Sedimentation Rate (ESR)?
EDTA Whole blood (Lavender Top)
6
What specimen is used in Reticulocyte Count?
EDTA Whole blood (Lavender Top)
7
What specimen is used in Prothrombin Time?
Citrated Plasma (Blue Top)
8
What specimen is used in Activated Partial Thromboplastin Time?
Citrated Plasma (Blue Top)
9
What specimen is used in D-dimer?
Citrated Plasma (Blue Top)
10
What specimen is used in Clotting Time & Bleeding Time?
Capillary Blood
11
What specimen is used in Malarial Smear?
Capillary Blood
12
What specimen is used in Peripheral Blood Smear (PBS)?
Capillary Blood
13
Turn around time STAT:
1 hour
14
It is not applicable for ESR determination
Turn around time STAT: 1 hour
15
Hematology Analyzers
• Beckman Coulter Ac.T 5 Diff Analyzer
• Beckman Coulter HmX AL Analyzer
• ACL Elite Pro
16
Hematology Analyzer for coagulation tests
ACL Elite Pro
17
Hematology Analyzer for CBC test
• Beckman Coulter Ac.T 5 Diff Analyzer
• Beckman Coulter HmX AL Analyzer
18
It is a fully automated hematology analyzer providing a complete WBC five-part differential, which is determined simultaneously by the AcV (Absorbance Cytochemistry and Volume) Technology and WBC/
Beckman Coulter Ac.T 5 Diff Analyzer
19
Beckman Coulter Ac.T 5 Diff Analyzer Small Sample Volume for CBC:
30 uL
20
Beckman Coulter Ac.T 5 Diff Analyzer Small Sample Volume for CBC + Diff:
53 uL
21
Beckman Coulter Ac.T 5 Diff Analyzer Throughput
up to 60 samples/hour
22
Beckman Coulter Ac.T 5 Diff Analyzer Sample Stability CBC:
48 hours @ room temp.
23
Beckman Coulter Ac.T 5 Diff Analyzer Sample Stability Diff:
24 hours @ room temp.
24
Beckman Coulter Ac.T 5 Diff Analyzer Reagents
• Diluent, 20 L
• Hgb Lyse, 400 ml
• WBC Lyse
• Diff Fix
• Diff Rinse
25
It is used for counting and differentiating blood cells
Diluent, 20 L
26
It dilutes whole-blood samples
Diluent, 20 L
27
It stabilizes cell membrane for accurate counting and sizing
Diluent, 20 L
28
It conducts aperture current
Diluent, 20 L
29
It rinses instrument components between analyses
Diluent, 20 L
30
It is used to lyse blood cells and to determine hemoglobin concentration
Hgb Lyse 400 ml
31
It is used to lyse red blood cells for the leukocyte count and to differentiate poly-nuclear basophils.
WBC lyse
32
It is used to lyse erythrocyte, fix leukocytes, and differentially stain granules of monocytes, neutrophils, and eosinophils
Diff Fix
33
It is used as a rinsing agent
Diff Rinse
34
A hematology quality control material used to monitor the performance of Ac.T 5 Diff analyzers in conjunction with the instrument's reagent system
Ac.T 5 Diff Control Plus
35
It is vailable in three levels (low, normal, and high)
Ac.T 5 Diff Control Plus
36
Ac.T 5 Diff Control Plus Open stability:
15 days
37
Ac.T 5 Diff Control Plus Storage:
2 - 8°C
38
Beckman Coulter Ac.T 5 Diff Analyzer Machine Linearity Parameters:
• WBC
• RBC
• Platelet
• Hemoglobin
• Hematocrit
39
WBC unit
10^3L
40
RBC unit
10^6L
41
Platelet unit
g/dL
42
Hemoglobin unit
10^3L
43
Hematocrit unit
%
44
Beckman Coulter Ac.T 5 Diff Analyzer:
WBC Linearity Range
0.5 to 80.0
45
Beckman Coulter Ac.T 5 Diff Analyzer:
RBC Linearity Range
0.20 to 7.50
46
Beckman Coulter Ac.T 5 Diff Analyzer:
Platelet Linearity Range
10 to 1,000
47
Beckman Coulter Ac.T 5 Diff Analyzer:
Hemoglobin Linearity Range
2.5 to 23.0
48
Beckman Coulter Ac.T 5 Diff Analyzer:
Hematocrit Linearity Range
11.6 to 55.0
56.0 to 62.4
49
WBC Difference (Whichever is Greater)
± 0.2 or ± 3%
50
RBC Difference (Whichever is Greater)
± 0.05 or ± 2%
51
Platelet Difference (Whichever is Greater)
± 10 or ± 6%
52
Hemoglobin Difference (Whichever is Greater)
± 0.3 or ± 2%
53
Hematocrit Difference (Whichever is Greater)
± 2 or ± 3%
± 5 or ± 5%
54
It is a quantitative, automated hematology analyzer and WBC differential counter for invitro diagnostic use in clinical laboratory
Beckman Coulter HmX AL Analyzer
55
Beckman Coulter HmX AL Analyzer Modes of Operation:
• Primary Mode
• Secondary Mode
56
Closed-Vial or Automatic Mode
Primary Mode
57
Autoloader uses the rocket bed and sensors to move specimen tube holders called cassettes from the loading bay to a cap-baying station, then to the unloading bay
Primary Mode
58
Primary Mode aspirates ______ uL of sample from each tube
185 uL
59
Open-Vial or Manual Mode
Secondary Mode
60
Secondary Mode aspirated ______ uL of sample from each tube via the aspi
125 uL
61
Beckman Coulter HmX AL Analyzer Reagents
• ISOTON III diluent
• LYSE III lytic reagent
• Erythrolyse II erythrocyte lytic reagent (also called PAK LYSE)
• StabiLyse leukocyte preservative (also called PAK PRESERVE)
• COULTER CLENZ cleaning agent
62
It is also called PAK LYSE
Erythrolyse II erythrocyte lytic reagent
63
It is also called as PAK PRESERVE
StabiLyse Leukocyte Preseevative
64
The material used for quality control of CBC and DIFF parameters
HmX 5C Cell Control
65
HmX 5C Cell Control Three levels of control with varying mixtures of normal and abnormal values of:
Normal
Abnormal 1
Abnormal 2
66
HmX 5C Cell Control Storage:
2 - 8°C
67
HmX 5C Cell Control Open Stability:
13 days or 13 events ( whichever comes first
68
Daily quality control check to verify performance of the VCS technology TTM components in both the DIFF and Retics modes.
Latron Control and Primer
69
Contains a surfactant to remove bubbles and clean the sample tubing and pathway from the tip of the aspirate probe to and through the flow cell
Latron Primer
70
Contains specific size latex particles with a predetermined volume, conductivity and laser light scatter
Latron Control
71
Beckman Coulter HmX AL Analyzer Machine Linearity Parameters:
• WBC
• RBC
• Hemoglobin
• MCV
• Platelet
• MPV
72
MCV unit
fL (femtoliters)
73
MPV unit
fL
74
Beckman Coulter HmX AL Analyzer:
WBC Linearity Range
0.0 - 99.9
75
Beckman Coulter HmX AL Analyzer:
RBC Linearity Range
0.0 - 7.00
76
Beckman Coulter HmX AL Analyzer:
Hemoglobin Linearity Range
0.0 - 25.0
77
Beckman Coulter HmX AL Analyzer:
MCV Linearity Range
50 - 150.0
78
Beckman Coulter HmX AL Analyzer:
Platelet Linearity Range
0.0 - 999
79
Beckman Coulter HmX AL Analyzer:
MPV Linearity Range
5.0 - 20.0
80
It iis an electronic method for counting and sizing particles
Coulter Principle
81
it is based on the fact that cells, which are poor conductors of a weak current, will interrupt the current flow.
Coulter Principle
82
• The cells are suspended in a conductive diluent and are pulled through the apperture by low vacuum
Coulter Principle
83
this creates a momentary increase in resistance to the electric flow.
Coulter Principle
84
• The resistance creates a pulse that is sensed and counted by the instrument as a particle
Coulter Principle
85
the amount of resistance (the amplitude of each pulse) is directly related to the size (volume) of the particle that produced it
Coulter Principle
86
Ac. T 5 Diff Analyzer & HmX AL Analyzer Measurement in WBC
Coulter Principle
87
Ac. T 5 Diff Analyzer & HmX AL Analyzer im Hemoglobin
Photometric
88
Ac. T 5 Diff Analyzer in Hematocrit
Derived from RBC Histogram
89
HmX AL Analyzer Measurement in Hematocrit
Calculated (RBC x MCV) / 10
90
Ac. T 5 Diff Analyzer Measurement in Segmenters, Lymphocytes, Monocyte, Eosinophils and Basophils
Impedance with hydrofocus
91
HmX AL Analyzer Measurement in Segmenters, Lymphocytes, Monocyte, Eosinophils and Basophils
Derived from WBC scatterplot using VCS technology
92
Ac. T 5 Diff Analyzer & HmX AL Analyzer Measurement in Platelet Count
Derived from PIt Histogram
93
Ac. T 5 Diff Analyzer & HmX AL Analyzer Measurement in RBC
Coulter Principle
94
Ac. T 5 Diff Analyzer Measurement in MCV
Calculated: (Hct/RBC) x 10
95
HmX AL Analyzer Measurement in MCV
Derived from RBC Histogram
96
Ac. T 5 Diff Analyzer & HmX AL Analyzer Measurement in MCH
Calculated: (Hgb/RBC) x 10
97
Ac. T 5 Diff Analyzer & HmX AL Analyzer Measurement in MCHC
Calculated: (Hgb/Hct) x 100
98
Ac. T 5 Diff Analyzer & HmX AL Analyzer Measurement in Mean Platelet Volume
Derived form PIt Histogram
99
Ac. T 5 Diff Analyzer & HmX AL Analyzer Measurement in Red Cell Distribution Width
Derived from RBC Histogram
100
It is a fully automated coagulation system for specific clinical use in hemostasis laboratory for dotting, chromogenic, special assay and immunological testing
ACL ELITE PRO
101
What are the tests ACL ELITE PRO used to perform?
• Coagulometric Tests
• Absorbance Tests
• Immunological Tests
• Special Tests
102
Coagulometric Tests:
• Protrombin Time
• Activated Partial Thromboplastin Time
• Thrombin Time
103
Absorbance Tests:
• Antithrombin
• Protein C
• Plasminogen
• Fibrinogen
104
Immunological Tests:
• D-Dimer
• Von Willebrand Factor - Activity and Antigen
•Free Protein S
105
Special Tests:
• LAC Screen and Confirm
• Silica Clotting Time Screen and Confirm
106
Coagulometric Tests performed in EACMed laboratory
• Protrombin Time
• Activated Partial Thromboplastin Time
107
Throughput: Up to _____ samples per hour for PT - Fibrinogen
175 samples
108
Throughput: Up to _____ samples per hour for APTT
125 samples
109
Turn-around-time: PT/PT - Fibrinogen: ____minutes from standby
4.5 minutes
110
Turn-around-time: PT/PT - Fib/APPT: ___ minutes from standby
8 minutes
111
ACL ELITE PRO sample tray is _____ samples
40 samples
112
ACL ELITE PRO _____ and _____ sample cups
0.5 and 2.0 sample cups
113
True or False: ACL ELITE PRO sample tray is a full draw tubes
True
114
ACL ELITE PRO reagent positions
Up to 22 total positions
115
Ac. T 5 Diff Analyzer Complete Blood Count (Automated): Startup Acceptable Value of WBC
0.3 x 10^3/L
116
Ac. T 5 Diff Analyzer Complete Blood Count (Automated): Startup Acceptable Value of RBC
0.03 x 10^6/L
117
Ac. T 5 Diff Analyzer Complete Blood Count (Automated): Startup Acceptable Value of Hemoglobin
0.3 g/dL
118
Ac. T 5 Diff Analyzer Complete Blood Count (Automated): Startup Acceptable Value of Platelet
7.0 x 10^3L
119
After the analysis, review the primer results at the DMS. If count is unacceptable:
Rerun the Latron Primer
120
After the analysis, review the primer results at the DMS. If count is acceptable:
Run the Latron Control
121
Reconstitute with 8.5 mL PT Buffer (5 days upon reconstitution)
PT Fibrinogen HS Plus
122
Liquid ready reagent and has 30 days stability upon opening.
APTT Reagent Synthasil
123
Reconstitute with 1 mL distilled water (24 hour stability upon reconstitution).
Normal Control Assayed (Normal Control)
124
Reconstitute with 1 mL distilled water (24 hour stability upon reconstitution.
Calibration Plasma (Normal Pool)
125
True or False: The leukocytes are counted in the four large squares
True
126
True or False: Cells that touch the top and right lines of a square should not be counted.
True
127
True or False: Cells on the bottom and left side should be counted.
True
128
Review the example computation
Number of leukocytes counted in 4 squares = 188
Number of leukocytes per liter (188 x 0.05) x 10^9
Result Reported: 9.4 x 10^9
129
Characteristics of satisfactory smear include the following:
1. There should be no lines extending across or down through the smear.
2. The smear must be smooth at the end, not ragged and lined.
3. The smear must not be too long and too thick.
4. The smear must not contain holes because a greasy slide has been used
130
It may be done on a smear to verify a questionable analyzer result.
Platelet estimation
131
It is derived by correlating a machine count and a smear count, as follows:
Platelet Estimation Factor
132
Platelet Estimation Factor Formula:
MC/SC= iPEF
PEF = Total iPEF ÷ 30

Legend:
MC - Machine Count
SC - Smear Count
iPEF - Individual PEF
133
Formula used to calculate the percent erythrocytes
Number of reticulocytes counted/1000 RBC x 1,000 = Reticulocyte ct. in %
134
Prothrombin Time Reference Range
11.8 - 15. 2 seconds
135
Prothrombin Time % Activity
70 - 100%
136
Prothrombin INR
0.80 - 1.20
137
Activated partial thromboplastin time (APTT)
25.4 - 38. 4 seconds
138
ESR: 0 - 18 years
0 - 10 mm/hr
139
ESR: > 18 years (Male)
0 - 15 mm/hr
140
ESR: > 18 years (Female)
0 - 20 mm/hr
141
Reticulocyte Count: > 18 years (Male)
0.5 - 1.5 %
142
Bleeding Time: > 18 years (Male)
1 - 3 minutes
143
Clotting Time: > 18 years (Male)
3 - 5 minutes
144
It aims to help laboratories attain accurate and reliable analytical results and achieve inter-laboratory comparability as well.
National External Quality Assessment Scheme (NEQAS) Enrollment
145
It is one of the requirements for the renewal of the License to Operate (LTO) of Clinical Laboratories of all category.
National External Quality Assessment Scheme (NEQAS) Enrollment
146
Reference Laboratory for Hematology:
National External Quality Assessment Scheme (NEQAS) Enrollment