1The factors that affect x-ray emission under the direct control of the radiographer are called the____________ factors.
prime
2Milliampere second directly affects each of the following except?
- density
- x-ray output
- quantity
- quality
3The factors that directly affect x-ray quality are?
- kVp
- filtration
- both of these
- neither of these
4If the mAs of a radiograph is increased from 10 to 20, the resulting radiograph will exhibit?
increased exposure
5The relationship between mAs and exposure is?
direct
6Increasing the kVp on an x-ray control panel will cause____________across the x-ray tube.
an increase in the speed of electrons
7Explain the reciprocity law. Give a mathematical example in your explanation.
Equal mAs gives equivalent exposure with different mA/time combinations; 100 mA × 0.3 s = 200 mA × 0.15 s = 30 mAs.
8Increasing the energy of an incident electron will result in the production of an x-ray photon with?
greater energy
9If the kVp is doubled, the amount (quantity) of the x-ray photons approximately?
increases fourfold
10An increase in kVp by 15% will cause an appropriate_______in the exposure.
doubling
11Adjustments in kVp “should” be used to control what?
contrast
12X-ray intensity is measured in?
roentgens (R)
13The relationship between the intensity of radiation and distance is the?
inverse square law
14Excessive mAs will result in which type of radiographic image?
overexposed
15What is an exposure index number? Or an S number?? Why are their values important?
A digital indicator of image receptor exposure used to evaluate whether exposure is too low or excessive.
16Distance and intensity exhibit which type of relationship?
inverse-square
17What is Dmax?
Maximum optical density of a film radiograph.
18T/F: kVp has no impact on radiographic exposure.
False
19Given 34 mA and an exposure time of 0.30 second, calculate the mAs.
10.2 mAs
20Given 15 mAs and a milliamperage of 150, calculate the exposure time.
0.1 s
21An initial x-ray is taken using the technical factors of 140 mA at 2 seconds. There is motion on the radiograph, but the radiographer wants to maintain radiographic exposure. If the exposure time is reduced to 1.5 seconds, what would the new mA be?
186.67 mA
22An image is taken using 12 mAs at 60 kVp. In order to double the exposure, what kVp should be used?
69 kVp
23An image is taken using 5 mAs and 55 kVp. If the kVp is changed to 63 kVp, what new mAs would be needed to maintain the exposure?
2.5 mAs
24An x-ray exposure of 100 mR is recorded at a distance of 44 inches. If the same technical factors are used, what will the exposure be if the distance is decreased to 40 inches?
121 mR
25An x-ray exposure of 250 mR is recorded at a distance of 72 inches. If the same technical factors are used, what will the new exposure be when the distance is decreased to 64 inches?
316.41 mR
26A 15% increase in kVp approximately ______ receptor exposure if mAs stays constant.
doubles
27To maintain receptor exposure after increasing kVp by 15%, reduce mAs by ______.
half
28To maintain receptor exposure after decreasing kVp by 15%, ______ mAs.
double
29The formula relating tube current, time, and charge is mAs = ______ × ______.
mA | seconds
30The exposure maintenance formula for a change in SID is mAs₂ = mAs₁ × ______.
(SID₂/SID₁)²
31At a fixed mAs, doubling SID reduces receptor intensity to ______.
one-fourth
32At a fixed SID, doubling mAs will ______ the number of x-ray photons.
double
33At higher diagnostic kVp, photoelectric absorption generally ______ relative to Compton scatter.
decreases
34The minimum aluminum HVL specified in the study materials for an 80-kVp beam is ______.
2.35 mm Al
35Why is a vacuum needed inside the x-ray tube?
To prevent gas collisions and permit efficient electron travel.
36In the diagnostic energy range, which interaction is most responsible for occupational radiation exposure to staff?
Compton interaction
37Differential absorption increases primarily when:
- kVp is increased, and atomic number of tissue is decreased
- kVp is decreased, and atomic number of tissue is increased
- mAs is decreased and SID is increased
- SID is increased and filtration is increased
38Which statement about Compton scatter is true?
- Compton scatter increases with increased atomic number tissues
- it results in total absorption of the incident photon
- It degrades the image contrast and contributes to fog
- it predominates below 20 kVp
39The photoelectric effect is more likely to occur when photon energy is:
slightly higher than the electron binding energy of a K shell electron
40At 70 kVp without contrast media, which tissue will exhibit the GREATEST photoelectric absorption?
bone
41Increasing kVp from 70 to 90, with mAs adjusted to maintain receptor exposure, generally causes:
more Compton interactions
42Which of these would NOT occur in a coherent scatter interaction?
- direction change of the photon
- vibration of electron(s)
- Ionization of the atom
- No ionization of the atom
43Pair Production requires a photon energy of at least:
1.02 MeV
44What is backscatter?
Photons scattered back toward the source, opposite the incident direction.
45What is attenuation?
Reduction in beam intensity as photons pass through matter.
46In a Compton interaction, what is the dislodged electron called?
recoil electron
47What term describes the unwanted exposure caused by scattered photons?
radiation fog
48When a positron and an electron combine, what reaction occurs?
annihilation reaction
49What determines optical density in screen-film radiography?
deposits of silver
50An incident electron is an ______ electron.
incoming
51The photoelectric effect involves complete ______ of the incident photon.
absorption
52The electron ejected during photoelectric absorption is a ______.
photoelectron
53For photoelectric absorption, incident photon energy must exceed the electron’s ______.
binding energy
54Photoelectric absorption is more likely when tissue atomic number is ______.
higher
55Which interaction is responsible for improved subject contrast between bone and soft tissue?
Photoelectric absorption
56When Compton scattering occurs, the incoming x-ray photon changes ______.
direction
57The Compton photon transfers some energy to an ejected ______ electron.
recoil
58The scattered photon from a Compton event has ______ energy than the incident photon.
lower
59Compton scatter is a major source of occupational ______ exposure.
radiation
60Coherent scatter generally involves photon energies of approximately ______ or lower.
10 keV
61During coherent scatter, ______ occurs because the atom ejects no electron.
no ionization
62In coherent scatter, the photon changes direction without changing its ______.
energy
63How does Thomson scatter differ from Rayleigh scatter?
Thomson involves one electron, whereas Rayleigh involves the atom’s electrons collectively.
64What are the five major photon interactions with matter?
1. Coherent scattering; 2. Photoelectric absorption; 3. Compton scattering; 4. Pair production; 5. Photodisintegration
65Which two photon interactions dominate diagnostic x-ray imaging?
1. Photoelectric absorption; 2. Compton scatter
66Pair production creates one ______ and one ______.
positron | electron
67Pair production occurs near the ______ of an atom.
nucleus
68Annihilation converts a positron and electron into ______.
photons
69In photodisintegration, a high-energy photon is absorbed by the ______.
nucleus
70Photodisintegration typically requires photons of approximately ______ or more.
10 MeV
71What occurs in a characteristic x-ray interaction?
An incident electron ejects an inner-shell electron, creating a vacancy.
72An outer-shell electron filling an inner-shell vacancy emits a ______ photon.
characteristic x-ray
73The succession of outer-shell electrons filling inner-shell vacancies is a characteristic ______.
cascade
74At the end of a characteristic cascade, the electron vacancy moves toward the ______ shell.
outermost
75Bremsstrahlung radiation is produced when an incident electron is deflected by the ______.
nuclear electric field
76Most diagnostic x-ray photons come from ______ interactions.
bremsstrahlung
77Which interaction can occur only above 1.02 MeV?
- Coherent scatter
- Pair production
- Photoelectric absorption
- Compton scattering
78What is the effect of scatter on radiographic contrast?
It lowers contrast and adds unwanted fog.
79Which term describes the reduction of photons in a beam passing through tissue?
Attenuation
80What is the difference between attenuation and transmission?
Attenuation removes photons from a beam, whereas transmission describes photons passing through material.
81What must happen to an incident photon in photoelectric absorption?
It is completely absorbed and ceases to exist.
82Which two factors most favor photoelectric absorption?
1. High atomic number; 2. Photon energy just above binding energy
83What two outcomes can produce attenuation of the primary x-ray beam?
1. Absorption; 2. Scattering
84Which interaction produces a recoil electron and a lower-energy scattered photon?
- Photoelectric absorption
- Compton scattering
- Coherent scattering
- Photodisintegration
85Which mechanism gives an emitted photon after an outer-shell electron fills an inner-shell vacancy?
- Bremsstrahlung
- Characteristic radiation
- Compton scattering
- Coherent scatter
86What is the approximate rms voltage of a single phase sine wave with a peak of 110 kVp?
78 kVp
87Each of the following is a part of the cathode assembly EXCEPT:
- the filament
- the stator
- the focusing cup
- the negative end’s associated wiring
88Each of these is a material of choice for the filament, EXCEPT:
- copper
- tungsten
- rhenium
- molybdenum
89Filament materials are chosen for their?
high melting points
90With the anode heel effect, there is a____________ greater output of energy at the cathode end.
45%
91If I was imaging a patient's femur, and trying to use the anode heel effect to my advantage, I would place the____________ end of the femur under the cathode end.
proximal
92Which of the following would affect the production of an electron cloud?
- filament diameter
- filament length
- filament temperature
- all of these
- none of these
93A focusing cup has a____________ charge.
negative
94The rotor is located____________ the stator, and____________ the envelope.
inside | inside
95Pitting of the anode commonly occurs?
with extended use
96Why is a vacuum created in the tube?
- to remove gas
- to remove air
- both of these
- neither of these
97Insulation of the high voltage components of the tube and absorption of the heat produced by x-ray production is achieved through the use of?
dielectric oil
98The function of the rotor and stator assembly is to?
rotate the anode
99A(n)____________ relationship exists between the actual focal spot and the effective focal spot.
direct
100The kVp control is found between the?
incoming line and exposure switch
101Sometimes it is justified to sit on the rotor.
True
102Grid biased tubes are most often seen in:
fluoroscopy
103When the ball bearings become imperfectly round, it leads to?
rotor wobble
104Patient scatter often causes “ghosting” of structures adjacent to the edge of the primary beam. (Missed on test)
105How long is the average x-ray tube's filament life?
- 3 to 4 hours
- 5,000 to 7,000 exposures
- both of these
- neither of these
106With the space charge effect, accumulated electrons around the heated filament repel additional electrons, limiting further emission.
True
107The use of pulsed fluoroscopy:
decreases patient dose
108The expandable gasket of the x-ray tube:
allows the dielectric oil to expand when heated
109Coherent scatter may also be referred to as:
- classical scatter
- unmodified scatter
- both of these
- neither of these
110When x-rays interact with the body:
- they can pass through unaffected
- they can be absorbed
- they can scatter
- all of these
- none of these
111An interaction that occurs when an incident electron interacts with a loosely bound outer-shell electron.
Compton scatter (the test uses “incident electron,” but the incoming particle is an x-ray photon).
112What does NEMA stand for?
National Electrical Manufacturers Association
113Almost all electron kinetic energy deposited at the target becomes ______.
heat
114The K-shell binding energy of tungsten is approximately ______.
69.5 keV
115The K-shell binding energy of lead is approximately ______.
88 keV
116Which event causes no ionization of the atom?
- Photoelectric absorption
- Compton scattering
- Coherent scatter
- Pair production
117What is a grid-biased tube used to control?
Rapid x-ray on/off pulsing by regulating the electron cloud.
118What is the typical filament thickness stated in the study sets?
0.1–0.2 mm
119What are the typical filament width and length?
1–2 mm wide; 7–15 mm long
120Why does tungsten vapor on the envelope reduce tube output?
The deposited coating increasingly absorbs the useful x-ray beam.