1
degree of sharpness of structural lines on a radiograph
detailecorded detail
2
ability to visualize recorded detail when image contrast and optical density are optimized
how well the radiographers see the image
visibility of detail
3
a measure of the degree of radiographic film darkening
optical density
4
sensitivity of the film to x-ray
bpth influences resolution and noise
speed
5
geometric factors
magnification
distortion
motion blur
focal spot blur
heel effect
6
if the object on the radiograph appears bigger than the represented object
it is the size and shape distortion
magnification
7
to avoid magnification, use:
large SID as possible
small OID/object close to IR
8
SID standard for chest
180cm=70inch
9
SID standard for routine examination
100cm=39inch
10
SID standard for special studies
90cm=35inch
11
when the part is distorted, _ is also reduced
spatial resolution
12
types of distortion
shape distortion
spatial distortion
13
unequal magnification of different portions of the same object
shape distortion
14
conditions that contributes to shape distortion
object thickness
object position
object shape
15
it will appear more distorted
thick object
16
reduction of the image size
foreshortening
17
increase in foreshortening as the _ and _ increases
angle and inclination
18
longer in image size
elongated
19
misinterpretation in the image of the actual spatial relationship among the objects
spatial distortion
20
refers to the blurred margin at the edge of the objects
results to the loss of sharpness
it is the most important factor for determining spatial resolution
focal spot blur
21
variation of radiation intensity across x-ray field and caused by attenuation of x-rays
heel effect
22
focal spot is small on the _ side and large on the _ side
anode;cathode
23
it is when patient moved during exposure
motion blur
24
procedures to reduce motion blur
use a shortest possible exposure time
restrict patient movement/motion by providing instruction or use restraining device
large sid
small oid
25
tools for improved radiographic quality
patient positioning
image receptor
selection of technique factors
26
Requires that the analytical structure under investigation be placed as close to IR
practical and that the axis of this should lie in a plane of the
CR should be incident of the center of the structure
The patient must be immobilized effectively to minimize motion blur
patient positioning
27
principles of image receptor
intensifying screen decreases patient dose by a factor at least 20
speed of IR increase, radiographic noise increase, spatial resolution decrease
28
selection of technical factors
reduce exposure time as possible
kVp controls contrast
mAs control optical densityadiographic density