1safelight illumination distance
3-4 ft above the loading area
2safe light illumination wattage
7.5 watts for 3ft distance
15 watts for 4ft distance
3filters out intensity and energy
filters
4filters out red, orange, yellow colors
for monochromatic film
amber filter
5amber filter appearance
brownish
6filters only the intensity, for monochromatic film or blue sensitive film
kodak wratten 6b filter
7filters out intensity and color (yellow and orange)
kodak gbx 2 filter
8for orthochromatic film (blue and green)
multi purpose filter
kodak gbx 2 filter
9if kodak gbx 2 filter is not available, _ may be used, check for light fogging
25 w bulb
10types of safelight
direct
indirect
11fixture type safelight
light is distributed directly
most common in hospital
direct safelight
12ceiling type safelight
light goes up first, then reflected
indirect safelight
13indirect safelight bulb
sodium vapor
14indirect safelight distance
6ft
15safelight test occurs
semi annual
16greater than 0.05 OD
safelight fog
17used to check safelight
densitometer
18dakroom can be adjacent to exposure room only if:
concrete:
hollow blocks:
wood:
greater than 6 inches
filled with cement
with 1.5 mm Pb
19pertaining to cleanliness;uncluttered counter top
efficient darkroom
20hypersensitivity to fumes
darkroom diseases