Chapter 5: Installing a Physical Network

106 flashcardsby Manethel
Study these flashcardsFree · spaced repetition · iPhone, Android, Mac & web

All cards

1
What connectors are used for most networking (excluding patch cables)?
110 Punchdown connectors (used in patch panels and wall jacks).
2
What tool is used to secure wires in a 110 Punchdown?
A 110 Punchdown tool (cuts wires and seats them in one motion).
3
Why is Cat rating important for patch panels/jacks?
All components (cables, panels, connectors) must match Cat ratings for performance.
4
What are the two wiring standards for Punchdowns?
568A and 568B (color-code guides are printed on panels/jacks).
5
How does a patch panel simplify wiring?
It handles wire splitting internally, so no need to manually split pairs (unlike RJ45 crimps).
6
What’s a key rule for high Cat-rated cables during Punchdowns?
Maintain ≤0.5 inch untwisted wire near the punch for signal integrity.
7
What’s the final step after punching down a wall jack?
Snap it into a faceplate for installation.
8
How does the speaker’s demo differ from professional work?
Pros are faster and more precise (e.g., minimize untwisting, avoid loose wires).
9
What’s the purpose of the horizontal run?
Connects patch panel (equipment room) to wall jack (user’s location).
10
Why is wire twist distance important in high-Cat cables?
To maintain signal integrity — typically, the untwisted portion should be under half an inch.
11
What is installed after punching down an RJ45 wall jack?
A cover is placed, and it’s snapped into a wall plate.
12
What is an MDF (Main Distribution Frame)?
Main Distribution Frame: Central equipment rack housing core network gear (patch panels, switches, routers) and external connections.
13
How does an IDF differ from an MDF?
Intermediate Distribution Frame: Satellite racks in multi-floor buildings, linking back to the MDF.
14
What is a "U" in rack mounting?
Rack Unit (1U = 1.75 inches): Standard height measurement for rack-mounted devices (e.g., 1U server, 2U panel).
15
Why are patch panels used?
To terminate horizontal cable runs (via 110 Punchdowns) and organize connections to switches.
16
What demarcates ISP/customer responsibility?
Demarcation Point (Demarc): Physical boundary (e.g., ISP’s splitter); customer owns extensions beyond it.
17
When is a demarc extension needed?
When the ISP’s demarc can’t reach the MDF (common in leased buildings).
18
What is the purpose of cable management in racks?
To organize patch cables, reduce clutter, and maintain airflow/serviceability.
19
Why are servers mounted on sliding rails?
For easy maintenance/access (e.g., "pizza box" servers slide out).
20
What role does the UPS play?
Provides backup power to critical rack equipment during outages.
21
What does the cable modem signify in this setup?
It acts as the customer-side demarc after an extension from the ISP’s original demarc.
22
What is the purpose of a patch panel?
To organize and terminate horizontal cable runs using 110 punchdowns and allow easy patching to switches.
23
What device connects all computers and devices on a network together?
A network switch.
24
What does cable management do in a rack?
It keeps patch cables neat and prevents them from hanging loosely or tangling.
25
What is the Demarc (Demarcation Point)?
The boundary between the service provider’s equipment and the customer’s network.
26
What is a Demarc Extension?
A run of cable that extends the service provider’s connection from a shared space into the customer’s equipment room.
27
What is the purpose of a 66 punchdown block?
It was the original patch panel for unshielded twisted pair, primarily used for telephone wiring.
28
Why are 66 blocks declining?
VoIP uses Ethernet (110 blocks/fiber), making analog voice obsolete.
29
How does fiber distribution differ from 110 blocks?
Uses LC/SC/ST connectors and patch panels; no punchdowns (fibers are spliced/terminated).
30
What cable type typically connects to a 66 block?
25-pair UTP (thick bundled cables for phone lines).
31
What modern cabling handles both voice and data?
Cat5e/Cat6 UTP (via 110 blocks or fiber for VoIP backbones).
32
Where would you find a fiber distribution panel?
Linking MDF to IDFs in multi-floor buildings or data centers.
33
Why are 66 blocks being phased out?
Because of the adoption of Voice over IP (VoIP) technology, which uses data networks for voice.
34
Can telephones and network connections be integrated into the same wall outlet?
Yes, by using structured cabling and terminating both on a 110 punchdown block.
35
What type of distribution panel is used for fiber optic cabling?
A fiber distribution panel.
36
What is the role of a fiber distribution panel?
It centralizes and organizes fiber connections, connecting switches to distribution points across a building.
37
Can 110 or 66 punchdown blocks be used for fiber?
No, fiber requires specialized distribution panels.
38
What does a fiber distribution panel typically connect to on one side?
A fiber switch.
39
What does the fiber distribution panel connect to on the other side?
Other floors, distribution switches, or fiber endpoints in the building.
40
What tool is used to trace unlabeled network cables?
Tone generator and probe (e.g., Fox and Hound).
41
Why disconnect the switch during tracing?
To prevent electrical interference with the tone signal.
42
How does an RJ11 connector work with an RJ45 port?
RJ11 fits into the center pins of an RJ45 socket.
43
What’s the purpose of labeling patch panels?
To avoid re-tracing cables and maintain organization.
44
Which Network+ domain covers cable tracing tools?
Domain 5.0 (Network Troubleshooting).
45
What does a tone generator do?
It sends a specific electrical tone through a cable to help locate it.
46
What does a tone probe do?
It detects the tone emitted by the tone generator to identify the cable.
47
Why is it important to unplug the network switch when using a tone probe?
Network activity can cause interference, making it difficult to hear the tone signal.
48
Can an RJ11 connector be used with an RJ45 jack?
Yes, RJ11 connectors can snap into RJ45 ports, using the center pins.
49
What is the main purpose of using a tone generator and probe in network troubleshooting?
To identify and trace unmarked or unknown cables in a network setup.
50
What real-world problem was solved using a tone generator and probe in the transcript?
Finding which patch panel port corresponded to a previously installed RJ45 wall outlet for a projector.
51
What does a wiremap test verify?
Correct pin termination (T568A/B) on both ends of a cable.
52
How does a TDR work?
Measures cable length by analyzing signal reflections.
53
What’s the max horizontal run per TIA-568?
90 meters (allowing 10m total for patch cables).
54
Why disconnect switches during continuity tests?
Prevents electrical interference with test signals.
55
What does it mean if wires don't light up or are out of order during Wiremap testing?
There may be missing wires or crossed pairs, indicating incorrect termination or damage.
56
What is continuity in cable testing?
It checks whether there is an actual electrical connection between the pins on both ends.
57
What is a TDR and what does it test for?
A Time Domain Reflectometer measures the length of a cable and detects faults along the run.
58
What are the three main tests you can perform yourself on a cable?
1) Wiremap, 2) Continuity, 3) TDR (length testing).
59
What is Crosstalk in cable testing?
Interference between wire pairs, often heard as crackling or static, which can degrade signal performance.
60
What are the two types of Crosstalk testers check for?
Near-end Crosstalk (NEXT) and Far-end Crosstalk (FEXT).
61
What does a solid link light indicate?
Physical layer connectivity (no data transmission guarantee).
62
How to test NIC hardware without external dependencies?
ping 127.0.0.1 (loopback test).
63
Two common causes of wall plate damage?
Cleaning crews yanking cables / improper RJ45 termination.
64
Where to start troubleshooting per structured cabling standards?
Work area (PC, patch cables, wall plate) before horizontal/equipment room.
65
Why is a loopback test unreliable for modern networks?
Only confirms NIC functionality, not external connectivity (e.g., switch misconfiguration).
66
What are the three components of a structured cabling system?
Work Area, Horizontal Cabling, Equipment Room.
67
Where should you begin troubleshooting if a user has no internet?
Start at the Work Area—check the PC, wall plate, and local patch cable.
68
How do you check for active network connections in Windows 10?
Go to Control Panel > Network and Sharing Center and look for active networks.
69
What do link lights on a NIC or switch indicate?
Solid = connection.

Blinking = activity.

No light = possible cable or port issue.
70
What does a down arrow on a NIC in Device Manager mean?
The network adapter is disabled.
71
What is the IP address for loopback testing?
127.0.0.1
72
Is loopback testing still commonly used?
No, but it's required knowledge for the Network+ exam.
73
What common physical issue can cleaning crews cause?
Frayed or damaged cables due to vacuums or poor routing.
74
What is the proper fix for a damaged wall plate connection?
Replace the RJ45 connector and re-punch the cable into the wall plate.
75
Why should you avoid troubleshooting in the equipment room first?
You might unplug or misconfigure something unrelated, making things worse.
76
All users down?
Check switch/UPS in equipment room.
77
TDR shows 10m on a 70m run?
Cable break 10m from tester.
78
Power dips logged at 3 AM?
Install a voltage monitor/UPS.
79
New elevator causes 5 PM outages?
EMI interference on nearby cables.
80
What is a key difference in troubleshooting when one user goes down versus all users connected to a switch go down?
One user down likely indicates a user-specific problem; all users down usually points to switch or equipment room issues.
81
What tool is used to test voltage dips and electrical issues in the equipment room?
A multimeter.
82
What is the purpose of a rack-mounted UPS in an equipment room?
To provide backup power and protect equipment from power outages or voltage dips.
83
What tool is used to test the continuity and length of horizontal cable runs?
A Time Domain Reflectometer (TDR).
84
How does a TDR help identify cable problems?
It measures cable length; a shorter-than-expected reading indicates a break or fault.
85
What can cause interference in a network even if cables were originally certified?
New building equipment (e.g., HVAC systems) or other devices introduced near cables.
86
What timing-related clue might help diagnose network interference problems?
Issues occurring at specific times of day, like 5:00 p.m. when many elevators run.
87
Attenuation fix?
Repeaters or shorter cable runs.
88
What problems can using the wrong cable type cause?
Distance limitations, reduced data rate, physical mismatches, and higher costs.
89
What are the two main types of fiber optic cables?
Single-mode and multi-mode fiber.
90
What is the distance range for single-mode fiber?

What is the distance range for multi-mode fiber?
Between 10 to 200 km.

Around 100 to 260 ft.
91
What are the indoor and outdoor categories for single-mode fiber?

What are the multi-mode fiber categories?
OS1: Indoor

OS2: Outdoor

OM1 through OM5

OM1/OM2: Short distances

OM3/OM4/OM5: Longer distances with better bandwidth
92
Why is shielding important in twisted pair cables?
Shielding protects against electromagnetic interference (EMI).
93
In what environments is Shielded Twisted Pair (STP) recommended?
Data centers

Medical environments with x-ray or MRI

Areas near power lines
94
Why is selecting the right voltage rating for a cable important?
Incorrect voltage can damage devices or start fires.
95
What causes signal degradation in network cables?
EMI, crosstalk, and attenuation.
96
What is crosstalk?
Unwanted signal interference between adjacent wires in a cable.
97
How can you test for crosstalk?
Use a cable tester with network analysis and TDR (Time-Domain Reflectometer).
98
What are the three types of crosstalk?
NEXT (Near-End Crosstalk)

FEXT (Far-End Crosstalk)

AXT (Alien Crosstalk)
99
What is NEXT and where is it measured?
Signal interference at the same end of a cable; measured at the transmitting end.
100
What is FEXT and where is it measured?
Signal interference at the opposite end; measured at the receiving end.
101
What is Alien Crosstalk (AXT)?
Crosstalk caused by EMI from nearby cables or devices, not in the same cable bundle.
102
What causes attenuation in copper cables?
Signal loss due to friction and resistance as the signal travels down the cable.
103
What is the max distance for twisted pair copper cable?
100 meters (328 feet)
104
How can improper cable termination affect a network?
Causes connectivity loss, low speed, or intermittent issues.
105
What is a common termination mistake?
Mixing up TX (transmit) and RX (receive) wires.
106
Why should you always test a cable after termination?
To detect hidden faults like poor transmission, bad impedance, or incorrect wiring.